✓ FDIS Approved Fire Door Specialists
✓ Certified Products · British Standards Installation

Fire Door Installation London & Home Counties

Supply and installation of certified fire door sets across all performance ratings — FD30, FD60, flat entrance, glazed and acoustic. New builds, like-for-like replacements and upgrades, all installed to British Standards with a full installation certificate on completion.

Certified Products
BS 8214 Standard
All Door Types
Installation Certificate

Fire Door Ratings We Install

FD30
30-min resistance
FD60
60-min resistance
  • Flat entrance door sets
  • Communal & corridor doors
  • Escape route doors
  • Fire-rated glazed doors
  • Acoustic fire doors
  • Third-party certified products
  • Installation certificate provided
🏅 Certified Products
📐 BS 8214 Standard
🚪 FD30 & FD60
📋 Installation Certificate
🏙️ London & Home Counties
What We Install

All Fire Door Types & Ratings

We supply and install fire doors across all standard performance ratings and building applications — from flat entrance doors in residential blocks to specialist acoustic fire doors in commercial buildings. Every door is a third-party certified product, installed to British Standards.

Whether your project requires a single replacement or a programme of installations across a large portfolio, we provide the same level of specification, installation quality and documentation throughout.

Certification Standard

Certified Products. British Standards Installation.

All fire doors we supply are third-party certified — Certifire, BM Trada Q-Mark or equivalent — confirming the product has been independently tested to the required fire resistance standard.

Every installation is carried out in accordance with BS 8214 and the manufacturer's installation specification — the two standards that govern how a certified fire door must be fitted to retain its fire resistance performance.

🔢
FD30 · FD60

FD30 & FD60 Door Sets

The two primary fire resistance ratings for most residential and commercial applications. FD30 provides 30 minutes of fire resistance; FD60 provides 60 minutes. We supply and install both ratings to the correct specification for the building type and risk.

🏠
FD30 · FD60

Flat Entrance Door Sets

Certified flat entrance fire doors for multi-occupied residential buildings — one of the most legally critical door types under the Fire Safety (England) Regulations 2022. Installed with correct seals, closers and ironmongery to the full FD specification.

🚶
FD30 · FD60

Communal & Corridor Doors

Fire doors for communal stairwells, corridors and lobbies in residential and commercial buildings — high-traffic locations where door condition and self-closing performance are critical to safe evacuation.

🚪
FD30 · FD60

Escape Route Doors

Fire doors on designated escape routes — stairwell entrances, final exit doors and escape corridor doors — installed to the specific requirements of the escape route designation and fire strategy.

🪟
FD30 · FD60

Fire-Rated Glazed Doors

Fire doors incorporating certified fire-rated glazing panels — suitable for locations where natural light, visibility or aesthetics are required alongside fire resistance performance. Both integrity-only and integrity-plus-insulation glazing available.

🔇
FD30

Acoustic Fire Doors

Specialist fire doors providing both fire resistance and acoustic performance — ideal for hotels, residential buildings with mixed use, or any environment where sound attenuation alongside fire protection is required.

📦
All Ratings

Full Door Sets

Every installation includes the complete fire door set where required — certified door leaf, fire-rated frame, intumescent and smoke seals, certified hinges, door closer and all specified ironmongery — as a complete, warranted assembly.

🔄
All Ratings

Retrofit Door Leafs

Where an existing frame is in sound condition and correctly specified, we can supply and fit a certified replacement door leaf as a retrofit — a cost-effective solution where full frame replacement is not required.

Installation Types

Every Installation Scenario Covered

From a single door replacement to a full new build programme — we carry out all fire door installation types across all building categories.

🏗️

New Build Installation

Supply and installation of fire door sets on new build residential and commercial developments — working with developers and principal contractors from specification through to completion.

🔄

Like-for-Like Replacement

Removal of existing non-compliant or end-of-life fire doors and installation of certified replacements to the same or upgraded specification — the most common installation type.

⬆️

Upgrade from Non-Fire-Rated

Replacement of existing standard doors with certified fire door sets — where a building has been assessed and fire doors are required in locations not previously protected.

🔩

Retrofit into Existing Frame

Installation of a certified fire door leaf into a sound existing frame — a cost-effective option where the frame meets the required specification and is in good condition.

📦

Full Door Set Install

Supply and installation of the complete certified door set — leaf, frame, seals, closers and ironmongery — as a fully warranted fire door assembly to the correct specification.

Standards & Certification

Why Certification Matters

A fire door is only as good as its certification and its installation. A product that has not been independently tested — or that has been installed incorrectly — will not perform to its rated resistance in a fire.

🏅

Certifire

Independent third-party product certification from Warrington Fire — the most widely recognised fire door certification scheme in the UK.

🏅

BM Trada Q-Mark

Third-party certification from BM Trada — recognised across the industry as evidence of tested and independently verified fire door performance.

📐

BS 8214

The British Standard for the installation of fire door assemblies — the authoritative standard governing how a certified product must be fitted.

📋

Installation Certificate

Issued on completion of every installation — confirming product certification reference, specification and compliance with BS 8214.

  • Third-Party Certified Products Only

    Every fire door we supply carries third-party certification — Certifire, BM Trada Q-Mark or equivalent — confirming independent testing to the rated fire resistance standard. We do not install uncertified products.

  • Installed to BS 8214

    All installations are carried out in accordance with BS 8214:2016 — the British Standard for the installation of fire door assemblies — and to the manufacturer's installation specification for the specific product.

  • Installation Certificate on Completion

    We issue a full installation certificate on completion of every project, documenting the doors installed, their certification reference, specification, installation standard and compliance status.

  • Why This Protects You

    In the event of a fire, an enforcement visit or an insurance claim, you need to demonstrate that your fire doors were correctly specified, certified products — and that they were installed correctly. Our documentation provides that evidence.

How It Works

From Specification to Certified Installation

A clear, well-managed process from initial enquiry through to handover — with full documentation at every stage.

1

Enquiry & Survey

We survey the location, assess the existing conditions and confirm the correct fire door specification for each opening.

2

Specification & Quote

We provide a clear itemised quote specifying the certified products, ratings, installation type and scope for each door.

3

Product Procurement

Certified fire door sets are procured to the agreed specification — third-party certified products, correctly rated hardware and seals.

4

Installation

Installation carried out to BS 8214 and the manufacturer's specification — every component correctly fitted, gapped and sealed.

5

Certificate Issued

Full installation certificate issued on completion — product certification references, specification and compliance confirmation.

Who We Work With

Installation for Every Building Type

We carry out fire door installations across a wide range of building types and client categories — delivering consistent specification, quality and documentation throughout.

🏠

Residential Landlords & Managing Agents

Replacement and upgrade of fire door sets in multi-occupied residential buildings — flat entrance doors, communal doors and escape route doors — to meet current regulatory requirements.

  • Flat entrance FD30 door replacements
  • Communal stairwell door upgrades
  • Minimal disruption to residents
🏢

Housing Associations & Local Authorities

Large-scale fire door installation programmes across residential portfolios — consistent specification, coordinated scheduling and centralised documentation across multiple properties and sites.

  • Portfolio-wide installation programmes
  • Consistent specification and quality
  • Centralised installation records
🏗️

Developers & Principal Contractors

New build fire door installation on residential and commercial developments — from specification and procurement through to installation and certification, working to programme and to the project's fire strategy.

  • New build specification advice
  • Programme-compliant delivery
  • Full installation documentation
FAQ

Frequently Asked Questions

What fire door ratings do you install?

+

We supply and install fire doors across all standard performance ratings — FD30 and FD60 — covering flat entrance doors, communal and corridor doors, escape route doors, fire-rated glazed doors and acoustic fire doors. All products are third-party certified.

Do your installed fire doors meet British Standards?

+

Yes. All fire doors we supply are third-party certified products — Certifire, BM Trada Q-Mark or equivalent — and every installation is carried out in accordance with BS 8214 and the manufacturer's installation specification. A full installation certificate is provided on completion.

Can you replace an existing fire door like-for-like?

+

Yes. Like-for-like replacement is one of our most common installation types. We remove the existing door set and install a certified replacement to the same or upgraded specification, correctly fitted and documented. Where the existing frame is sound, a retrofit leaf replacement may also be an option.

Do you carry out new build fire door installation?

+

Yes. We work with developers and principal contractors on new build projects — providing specification advice, certified product supply and installation across all fire door types and ratings, working to the project programme and fire strategy.

What documentation do you provide after installation?

+

We issue a full installation certificate on completion of every project, documenting each door installed, its certification reference, product specification, installation standard and compliance status. This forms part of your building's fire safety documentation.

Can you also inspect and maintain the doors you install?

+

Yes. As a full-service provider we offer FDIS-approved inspections, planned preventative maintenance contracts and remedial works alongside our installation service — providing a complete fire door compliance solution under one roof from day one.